Carlon Conduit Coupling, 1/2 in Trade, PVC
|
Carlon Conduit Coupling, 3/4 in Trade, Socket Connection, PVC
|
Carlon Conduit Adapter, 1/2 in Trade, Female Connection, PVC, Gray, 1-9/16 in Length, 1-7/64 in Diameter, Suitable for: SCH 40 and 80 Conduits, Includes: (30) Female Adapters
|
|
|
|
|
|
|
|
|
|
|
|
|
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed, RoHS Compliance.
|
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed, RoHS Compliance.
|
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.
|
|
|
|
|
|
|
|
|
|
|
|
|
Safe, non-conductive. SCH 40 non-metallic socket type coupling for joining SCH 40 non-metallic conduit. Will not rust or corrode. RoHS compliance, UL listed.
|
Carlon Conduit Adapter, PVC, 27/32 in L, 0.84 in Dia
|
Zinc die-cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. Fits 1/2 in knock outs.
|
|
|
|
|
|
|
|
|
|
|
|
|
Carlon Conduit Adapter, PVC, 29/32 in L, 1.05 in Dia
|
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA certified.
|
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA certified.
|
|
|
|
|
|
|
|
|
|
|
|
|
Carlon Conduit Adapter, 1 in Trade, Female Connection, PVC, Gray, 1-15/16 in Length, 1-5/8 in Diameter, Suitable for: SCH 40 and 80 Conduits
|
High-impact thermoplastic. Flame retardant to 105 deg C. Use with locknut to terminate threaded Rigid or IMC conduit to an outlet box. The rounded surface of the bushing prevents damage to wire insulation. Required by the NEC. UL listed and CSA approved.
|
Halex Conduit Locknut, 1/2 in Trade, Steel, Zinc, Suitable for: IMC Conduit or Various Threaded Fittings, Use with Rigid
|
|
|
|
|
|
|
|
|
|
|
|
|
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.. UL listed, RoHS Compliance.
|
Safe, non-conductive. SCH 40 non-metallic socket type coupling for joining SCH 40 non-metallic conduit. Will not rust or corrode. RoHS compliance, UL listed.
|
Carlon's Snap Strap? offers a unique support strap designed especially for the installation of PVC conduit. Also suitable for installations of rigid steel. This high-strength, non-metallic clamp allows conduit to expand and contract freely, eliminating the bowing commonly seen from the expansion and contraction of conduit caused by varying temperature changes. Finished installations have a neat, attractive appearance on exposed applications.
|
|
|
|
|
|
|
|
|
|
|
|
|
Zinc die-cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. UL listed.
|
Steel with zinc plating. Indoor or outdoor applications. Use to secure Rigid or IMC conduit or various threaded fittings to a steel outlet box or other metal enclosure.
|
For use with non-metallic solvent weld fittings. Non-conductive, impact, corrosion and sunlight-resistant. SCH 40. UL 651 Listed to the NEC by the ETL, UL listed.
|
|
|
|
|
|
|
|
|
|
|
|
|
Use to secure conduit to a metal beam. Clamps on beam, girder or similar structure to provide a mounting base for attachment of a conduit hanger, either directly or by means of a threaded rod. Eliminates need to drill hole through beam.
|
Zinc die-cast. Use to join two pieces of flexible metallic conduit (Greenfield) together.
|
Indoor or outdoor applications. To support EMT conduit.
|
|
|
|
|
|
|
|
|
|
|
|
|
Zinc die-cast. Indoor or outdoor applications. Use to reduce the entry size of a run of threaded conduit. UL listed.
|
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA certified.
|
Use to reduce the size of the conduit hole knockout opening in a steel outlet box or other metal enclosure. Must use one inside the enclosure opening and one on the outside. UL listed and CSA certified.
|
|
|
|
|
|
|
|
|
|
|
|
|
Indoor or outdoor applications. Use to secure rigid or I.M.C. conduit to wood, masonry or similar surfaces.
|
Innovative one-piece quick connect design for fast and easy installation. Suitable for damp locations. No glue or cement needed. Carlon Standard Blue. Concretetight when used with appropriate ENT.
|
Safe, non-conductive. For adapting SCH 40 non-metallic conduit to boxes, threaded fittings, metallic systems. Female threads one end, socket end on the other. Will not rust or corrode.
|
|